Duoyi DY219 Operating Manual - Page 9
Browse online or download pdf Operating Manual for Test Equipment Duoyi DY219. Duoyi DY219 12 pages. Battery tester
the internal resistance by the formula.
Disadvantages of this method:
(1) Just available for large capacitance battery or storage battery. The small
capacitance battery can not load 40-80A large current in 2-3 seconds.
(2) When the large current going through the battery, there comes out
polarization phenomenon from internal electrode, which can cause
polarization internal resistance. As a result it has to be tested in a short time.
Otherwise there is a large error of the internal resistance value.
(3) The internal electrode will be damage generally when large current go
through the battery.
The method of this tester:Battery is actually equivalent to an active
resistance. So we add a fixed frequency and small current to it, and then
sample the voltage value. Eventually the internal resistance can be figured
out after some operation such as rectificationand smoothing.
Advantages of this method:
(1) It can be used for checking almost all the batteries including low capacity
battery and internal resistance of the notebook battery exclusively.
(2) It will not harm the battery to use this method.
7. Specification Of Storage Battery
The data in the table is just for reference. Actual value must be referredto the
manufacturer.
7-1.JIS translation table
Battery
CCA
NEW JIS
OLD JIS
MF
CMF
26A17R
200
26A17L
200
26A19R
12N24-4
200 220 264
26A19L
12N24-3
200 220 264
28A19R NT50-N24 250
28A19L NT50-N24L 250
32A19R NX60-N24 270
295
Battery
CCA
NEW JIS
OLD JIS
MF
55B24RS
NT80-S6S
430
420
55B24LS
NT80-S6LS
430
420
55D26R
N50Z
350
440
55D26L
N50ZL
350
440
60D23R
520
60D23L
520
65D23R
420
540
14
75% 12.54V
50% 12.30V
25% 12.12V
Totally discharged 11.94V
CCA value 588CCA
Determine The Condition of Battery.
For 12/24V system in use of 24V test mode, CCA value refers to 1/2
value of the one set of two 12V series connection batteries.
Internal resistance 4.75mΩ
The higher of the CCA value , the lower of the internal resistance
normally.
Note: Different material of the battery produced by various
manufacturers can cause different internal resistance. So there is no fixed
standard. But there is little difference among the internal resistance of the
battery with the same model from the same manufacturer.
For 12/24V system in use of 24V test mode, internal resistance value
refers to total value of the one set of two 12V series connection batteries.
Life: Display the condition of the battery. Suggest replacing the battery
when it shows below 45%.
<45%
◆ Suggest replacing
CMF
The result indicates the battery is bad
500
500
and remains 32% of life. So suggest replacing
525
the battery.
525
◆ Life check OK, and voltage check low
The result indicates the battery is
580
good and full of 100% of life. But only 12.11V
75%
12.42V
50%
12.24V
25%
12.06V
Totally discharged 11.88V
7