DIS
Connection Details
Blue
Mains
Brown
Green/Yellow Earth (Ground)
The DCS 6000 system uses Cat5e, Cat6 or Cat7 F/UTP
DCS-LAN Chain
or U/FTP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
FTP
STP
UTP
Important: Use only F/UTP or U/FTP (screened) cables
and screened RJ45 connectors and not U/UTP cable, which
are unscreened.
How to wire a Cat5e (EIA 568-B) cable to a RJ45 con.:
Pin
Function
1
In-going +
ORG/WHT
2
In-going -
ORG
Accessories
EC 6001-0.5 Connection Cable 0.5 m ..................... 10 03 22500
Cat5e Connection Cables (AWG24)
EC 6001-01 Connection Cable 1 m .......................... 10 03 23101
EC 6001-02 Connection Cable 2 m .......................... 10 03 23201
EC 6001-05 Connection Cable 5 m .......................... 10 03 23501
Neutral
Live
New name
F/UTP
U/FTP
U/UTP
Connector #1
Connector #2
ORG/WHT
ORG
User Manual EX 6010 rev F.doc
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Important: If other color codes are used then the four pairs
are connected as follows:
Pair 2:
Pin 1 & 2
Pair 3:
Pin 3 & 6
Pair 1:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the wiring
spec. as stated in Cat5e (EIA 568-B) have to be
followed.
Note: Cat6 and Cat7 cables can normally only be terminated
in sockets (female) and not in cable plugs.
Cat6 and Cat7 can thus only be used for feeding cables
terminating in wall outlets or patch panels.
EC 6001-10 Connection Cable 10 m ....................... 10 03 24102
EC 6001-20 Connection Cable 20 m ....................... 10 03 24202
EC 6001-50 Connection Cable 50 m ....................... 10 03 24502
User Manual
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
19