Danish Interpretation Systems RP 6004 User Manual - Page 8

Browse online or download pdf User Manual for Repeater Danish Interpretation Systems RP 6004. Danish Interpretation Systems RP 6004 14 pages. Digital conference system

Danish Interpretation Systems

System design

There are no settings to be done on the RP 6004
Repeater.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6010
Central Unit.
And as so, the specification, which applies to each
of the chain outputs on the CU 6010 Central Units
does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004
Repeaters, bare in mind, that as the RP 6004
'Repeated chain' connector
When connecting the RP 6004 Repeaters to the CU
6010 the first EX is connected to the 'Loop
through' connector. The next RP 6004 Repeaters
can be connected to either the other 'Loop through'
connector or to one of the 'Repeated out'
8
Repeater is repeating only one of the four outputs A
(A1 or A2) or B (B1 or B2) the max. number of
languages configured on the four outputs (1, 2, 3
and 4) is totally max. 16.
If more languages are required, Interpreter sets for
those languages have to be connected either to an
other RP 6004 Repeater, which is connected to the
other of the two chains (A or B) on the CU 6010, or
directly to the other of the two chains (A or B) on a
CU 6010.
connectors. If using the 'Repeated' outputs two
more RP 6004 Repeaters can be connected
extending the maximum cable length in one chain
up to 680 m. The above schematic is showing the
connection using the ''Repeated out' connectors.
Manual 01 18 04466 Printed in Denmark
Appendix