Connecting the system
Power supply
Please connect the power jack at the rear to your wall outlet. You should
either use the provided power cord or another one allowed for your
homecountry specifications.
NOTE:
The power specifications on the rear must meet to your home coun-
try specifications.
The AMP I is a Class I-system and must be earthed. Please ensure a
stable earth connection.
Inputs
For connecting or removing a preamplifier, the AMP I has to be switched
off. Please ensure that all connector cables are in absolutely best condi-
tion.
The AMP I has two RCA inputs for the connection of a preamplifier, e.g.
Audionet PRE. Due to the dual mono construction, left and right inputs
are separated at the rear.
Please connect left and right input of the AMP I to the corresponding
outputs of your preamplifier.
Outputs / Loudspeakers
The AMP I has a protection circuit to prevent damage of the system in
case of short-circuit between the loudspeaker outputs. Nevertheless, to be
on the safe side your AMP I should be switched off while you are work-
ing on the cables between amplifier and loudspeakers.
Please connect the left and right loudspeaker outputs to the corresponding
inputs of your loudspeakers. You should pay attention to phase coinci-
dence of your connections. This means that the red outputs (+) of the am-
plifier are connected to the positive inputs of the loudspeakers (usually
red) and the white outputs (-) are connected to the loudspeakers' negative
3