Video Output
1
BNC video output port
Reset Switch (Reset)
2
Reset switch is used for restarting DN1126 or resetting DN1126 as Factory Default
(FD). Refer to '4.1. Factory Default Settings' for detailed procedures.
USB connector
3
USB connector is used for connecting the USB device with DN1126.
10 pin terminal block for D/I, D/O and serial communication – new version
4
will be RS-422/RS-485
D/I – Alarm Input
DN1126 provides 1 channel D/I (Alarm Input). It may be connected to either
voltage type sensor or relay type sensor as following Figure 4 and Figure 5. It
may be selected by software.
Please pay attention to electric characteristics during installation.
1
1
Figure 3. 10 pin terminal block
C
Figure 4. Voltage Type Digital Input Connection
C
Figure 5. Relay Type Digital Input Connection
+5V