(NOTE: 12 volt power supply and IRBug/IRFlood are supplied with IRTarget packages only)
FOR INSTALLATIONS USING AUDIOPLEX TECHNOLOGY
Using IRTarget Direct Wired to Emitters (no connector device)
MMX 4056
RED 12-15V (B+)
IRTarget
BLACK GROUND (GD)
YELLOW SIGNAL
BLUE SYS-TAT (Optional)
Using IRStation / IRZ-1/ Niles / Xantech Connector Blocks
MMX 4056
IRTarget
BLUE
YELLOW
BLACK
RED
WIRING DIAGRAMS
Termination Block
IR-TB
V
G
S
T
TM
IRStation (Back View)
OPTIONAL SYS-TAT
T
SIGNAL
S
GROUND (GD)
G
12-15V (B+)
V
T
S
G
V
T
S
G
V
NILES is a registered trademark of Niles Audio Corporation, Inc.
XANTECH is a registered trademark of Xantech Corporation.
AUDIOPLEX TECHNOLOGY
404 GWH P.O. BOX 440
MELVIN VILLAGE, N.H. 03850
1-800-257-2077 IN N.H. 1-603-544-8601
FAX: 1-603-544-8901
TM
INFRARED EQUIPMENT
IRBug/IRFlood or Emitter Plate
(up to 8 emitters in parallel)
S
S
GD
V
G
S
T
WHITE STRIPED
In-wall version shown, chassis version also available
IRStation (Front View)
SYS-TAT(optional)
T
SIGNAL
S
GROUND
G
12 VDC
V
T
S
G
V
T
S
G
V
DX
GD
UNREGULATED
12 VDC POWER
SUPPLY
OPTIONAL
12 VDC SYS-TAT
POWER SUPPLY TO
SWITCHED OUTLET
TEST
UNREGULATED
12 vdc system status(optional)
12 vdc power supply
1/8" test input connector
2004 - 1/22/04