Dantel 44022-00 Installation & Operation Manual - Page 5
Browse online or download pdf Installation & Operation Manual for Recording Equipment Dantel 44022-00. Dantel 44022-00 18 pages. Subscriber line interface module
![Dantel 44022-00 Installation & Operation Manual](/uploads/products/server2/1709582/1709582.jpg)
CIRCUIT DESCRIPTION
A
S
UDIO
ECTION
44022-00-0898 <90-00023>
Receive Circuit
NOTE:
Strap the 10 dB pad IN to prevent high level signals from
falsely turning on the mute FET. Strap the 10 dB pad OUT
only when incoming signal levels are too low to meet output
level specifications. Pad strapping does not apply when you only
use the summing inputs.
Active Hybrid Integrated Circuit
Transmit Circuit
P
5