TECHNICAL SPECIFICATIONS
DESCRIPTION
Input Voltage Range
Current Requirements
No relays Operating
One Relay Enabled
All Relays Enabled
Heat Dissipation
One Relay Enabled
All Relays Enabled
Current per Input to Operate
Control Lead Input Voltage
Minimum Operating
Maximum Release
Relay Contacts
Current Rating
Resistance
Operating Temperature
Physical Dimensions
Weight
P
4
AGE
OPERATION
T
he relays operate on any battery voltage from -5 to -60 VDC.
There is no latching capability. The relay contacts open when
voltage is removed. The individual LED should light on the front
panel as power is applied to each relay. This, however, does not
verify correct relay contact operation — only that power is
applied to that individual relay coil.
-21 to -56 VDC
@ -21VDC
@ -24 VDC
0.0 mA
0.0 mA
7.0 mA
8.0 mA
112.0 mA
128.0 mA
@ -21VDC
@ -24 VDC
0.50 Btu/Hr
0.66 Btu/Hr
8.0 Btu/Hr
10.5 Btu/Hr
0.13 mA @ -5 VDC; 2.75 mA @ -60 VDC
-2.75 VDC
-1.5 VDC
1 Amp @ 30 VDC
0.1 Ohm
0° to 55° C.
1.4" x 6.0" x 5.6"
7.5 Ounces
DESCRIPTION
@ -48 VDC
@ -56 VDC
0.0 mA
0.0 mA
11.0 mA
12.0 mA
176.0 mA
192.0 mA
@ -48 VDC
@ -56 VDC
1.8 Btu/Hr
2.3 Btu/Hr
28.8 Btu/Hr
36.7 Btu/Hr