How to replace the control panel,
Procedure
Follow these steps to replace the control board:
Step
1
Switch of all the power to the unit
2
Loosen the two straight slot screws on the power plug and remove the
power plug from the controller
3
Remove the 4 torx 20 screws that hold the controller
4
Take out the controller by turning it to the left
5
Remove the two 4-way multi plugs from the controller
6
Mount a new controller by following step 2 to 5 reversed and in opposite
order
7
Connect the power
Result: The test program runs through all functions.
Check that the unit does not come out with an alarm signal.
In case of an alarm signal, please see page 5
continued
Action
9