3.3 Parameter interface
Parameters can be set by a qualified person in order to make the heat pump more efficient
depending on the specific conditions of the swimming pool.
Parameter name:
Name of parameter. The following can be found:
Set:
Is not visible
when you scroll
through the list of
parameters.
Is visible when the
selected parameter
can be changed.
Value parameter:
Current value of the
selected parameter.
Any changes will be
saved automatically.
User editable parameter may be changed by the end user.
Installer editable parameters and factory settings may only be changed in a service center or by
similar qualified persons in order to avoid a hazard.
Please find a complete list and more information about each error in full version.
The display shows
Display lock:
for 3 seconds to unlock the display
Consitant parameter
User editable settings/parameter
Sensor settings/parameter
Installer editable settings/parameter
Factory editable settings/parameter
when there's no interaction for 5min. Press any button
.
Up:
Scroll up through the list of parameters.
Edit the value of the selected
parameter.
Down:
Scroll down through the list of
parameters.
Edit the value of the selected
parameter.
Set:
Press to enter or exit the
parameter menu.
ON/OFF:
Select the parameter you want
to edit
7