Operation Modes
MODE
STATUS LED
NORMAL
Green
(calibrated)
CALIBRATION
Green blinking slow
FORCE
Yellow
NOT CALIBRATED
Blue
TEMPORARY ERROR
Red
FATAL ERROR
Red blinking fast
*DMS = Dead Man Switch mode
NORMAL (Calibrated)
Status LED is green
•
The end points are programmed and the cover will not go outside these
limits.
•
The cover can be controlled locally (via the key switch) and remote (via
the LINKTouch), this in automatic mode and in DMS mode.
•
In automatic mode, a soft-start and soft-stop is active. The cover stops
when the calibrated open or close position is reached.
•
When the key switch is turned to the open or close position (or the open
or close button on the LINKTouch is pressed) during movement of the
cover, the cover stops immediately as an emergency brake.
•
In DMS mode, only the soft-start is active. The cover stops immediately
when the key switch (or LINKTouch button) is released.
•
When a LINKTouch is used, the cover indicates its position on the LINK-
Touch.
•
The relay for filtration pump is enabled when the cover is not in the cali-
brated open or close position.
14
COVER MOVEMENT
FILTERPUMP
Disabled when cover
Automatic or DMS*
is not at end position
DMS
Disabled
DMS, open and close
position temporary
Disabled
removed
Disabled when cover
DMS
is moving
DMS or no movement,
depending on error
Active
condition
No movement
Active
possible
CALIBRATION
The status LED blinks green.
The cover can be controlled locally (via the key switch) and remote (via Link-
Touch), but only in DMS mode: the cover stops immediately when the con-
trol is released.
The calibration procedure is explained in detail in topic "Calibration" (page 8) and
"correction" (page 9)
FORCE
The status LED is yellow.
This mode can be used to temporarily overrule the open and/or close posi-
tions of the cover when it is already calibrated. The cover can be controlled
locally (via the key switch) and remote (via LinkTouch), but only in DMS mode:
the cover stops immediately when the control is released.
NOT CALIBRATED
The status LED is blue.
The cover can be controlled locally (via the key switch) and remote (via Link-
Touch), but only in DMS mode: the cover stops immediately when the con-
trol is released.
TEMPORARY ERROR
The status LED is red.
The device indicates that an error is present. As soon as the error condition
disappears, the device continues in normal operation.
Possible error conditions are listed in the Troubleshooting topic below.
In case an temporary error occurs: shut down the device and restart. If the
error condition is not resolved, please contact your installer.
FATAL ERROR
The status LED is blinking red fast
The device shows a fatal error and cannot recover. Please contact your in-
staller.
15