The Binswitch Elite may be mounted horizontally or vertically. 4B offers two mounts, SMP or the
BMPG36 (see illustrations below). The end of the sensor must be at least one inch from the bin wall or
other metalwork.
It is important that the Binswitch is not located in the direct flow path of any abrasive material. However,
if the Binswitch must be located in the path of an abrasive material, use in conjunction with the BAS
(Binswitch Abrasion Shield).
Three alternative mounting methods are available for the Binswitch Elite, see figures A, B and C below:
Fig. A -
Cut and drill holes as shown and
attach mounting plate (SMP)
using six 5/16" x 3/4" (M8 x 20)
bolts, nuts and washers. Slide
Binswitch into position and
secure by tightening mounting
plate adaptor (BMPA).
DO NOT OVERTIGHTEN
Fig. B -
Cut holes as shown and attach
mounting gland (BMPG36) using
locknut. Slide binswitch into
position and secure with clamp.
DO NOT OVERTIGHTEN
Fig. C -
Cut and drill holes as shown.
Attach mounting plate (SMP)
using six 5/16" x 3/4" (M8 x 20)
bolts, nuts and washers. Slide
Binswitch into abrasion shield
(BAS) and tighten BAS into
mounting plate (SMP).
DO NOT OVERTIGHTEN
INSTALLATION
Minimum Projection
3/8" (10 mm)
Minimum Projection
3/8" (10 mm)
2"
(50 mm)
Locknut
Minimum Projection
3/8" (10 mm)
PAGE 7
Wall / Casing
Mounting Plate (SMP)
Binswitch
Mounting Plate Adaptor (BMPA)
1-1/4" Thread
Wall / Casing
Mounting Gland (BMPG36)
Binswitch
Wall / Casing
Mounting Plate (SMP)
Binswitch
Binswitch Abrasion Shield (BAS)
1-1/4" Thread
3/4" NPT Conduit
Adaptor (A34NPT)
3/4" NPT Conduit
Adaptor (A34NPT)
3/4" NPT Conduit
Adaptor (A34NPT)