APLOS ANGEL 600 GPD Instruction Manual - Page 4
Browse online or download pdf Instruction Manual for Water System APLOS ANGEL 600 GPD. APLOS ANGEL 600 GPD 9 pages. Direct flow reverse osmosis drinking water system
Parts and materials in contact with water
Part name
Composite filter element
made of PP cotton,
phosphate, and activated
carbon rods
RO membrane filter
* The service life of the filters are estimated based on the average daily pure water consumption of 20L in ordinary households and the inlet water
meets the following conditions: water temperature 5°C-38°C, inlet pressure 1-4 bar, pH 7.5+/-0.5, turbidity <1.0NTU, total dissolved solids (TDS)
≤500mg/L, total organic carbon (TOC) ≤1.0mg/L
* Filters should be replaced timely according to indicators to ensure high quality of purified water. The service life of the filter varies depending on
the inlet water quality and temperature, inlet pressure, daily usage of purified water, and operating environment.
Electric Control Schematic Diagram
Inlet solenoid
valve
Flush solenoid
valve
Power adapter
Specifications
Product name
Brand
Model
Filtration stages
Rated voltage
Rated power
Feed water requirements
Inlet water temperature
Operating temperature conditions
Inlet pressure
Operating pump pressure
Maximum daily production rate
Purified water production rate
(Recovery, %)
Material
PP filter housing, PP carbon
Phosphate particles, activated
carbon rods
PP filter housing, PA
Red
Green
Main control board
Direct flow reverse osmosis drinking
APLOS
Angel
4
220V~
60W
Municipal tap water or pre-treated well water
5°C-38°C
4°C-40°C
1-3 bar
4-6 bar
600 GPD
90L/h
65%
Model specifications
1199479
1199480
Red
Green
CPU
600 GPD
03
Quantity
Service life
6-12months
1
2-3years
1
High- pressure
switch
Booster pump