8

TECHNICAL DETAILS DX250 SA

Motor voltage
Current consumption
Power
Duty rating
Max. torque
Duration gate open/close
Operating Temperature
Weight

8.1 Internal operator wiring

13
1
3 2
5 4
1
2
3
4
13 internal wiring
A End-of-travel switch
gate opened

8.2 Abbreviations for colour identiying used

Abbreviations of the colours for identifying the cables,
conductors and components comply with the international
colour code according to IEC 757:
BK
black
BN
brown
GN
green
BU
blue
24 VDC
5 A
80 W
60%
180 Nm
13 - 24 sec. / 90°
-20 ÷ +60 °C
8.3 Kg
M
motor
C
F
O
C
M
O
1 2 3 4 5
-
M
motor
+
A
B
5
B End-of-travel switch
gate closed
RD
WH
YE
yellow
GY
11
9

INSPECTION AND MAINTENANCE

• The gate operator is maintenance-free.
• In the interest of your own safety, we recommend
having the gate system inspected and maintained by a
qualifi ed person in accordance with the manufacturer's
specifi cations.
Danger of injury due to unexpected gate travel!
Unexpected gate travel can result during inspection and
maintenance work if the gate system is inadvertently
actuated by other persons.
• Disconnect the mains plug and, if applicable, the plug
of the emergency battery when performing all work on
the gate system.
• Safeguard the gate system against being switched on
F
again without authorisation.
C
C
An inspection or necessary repairs may only be carried
out by a qualifi ed person. Contact your supplier for this
purpose.
A visual inspection may be carried out by the operator.
• Check all safety and protective functions monthly.
• Malfunctions and/or defects at hand must be rectifi ed
immediately.
• We would like to point out that any repairs not carried
out properly or with due professionalism shall render the
warranty null and void.

10 OPTIONAL ACCESSORIES

Optional accessories are not included in the scope of
delivery.
Loading of the operator by all electrical accessories:
max. 500 mA.
The following accessories are available:
• External radio receivers
• External impulse buttons (e.g. key switch)
• External code and transponder switches
• One-way photocell
• Warning lamps/warning lights
• Electric lock for post locking
• Electric lock for fl oor locking
• Stop plate
• Security contact-strip
• Spray-water protected junction box

11 DISMANTLING AND DISPOSAL

Note
When disassembling, observe the applicable regulations
regarding occupational safety.
Have a specialist dismantle the gate operator in the
reverse order of these instructions and dispose of it
properly.
red
white
grey
ENGLISH
WARNING!