Durite 0-441-15 Quick Start Manual - Page 2

Browse online or download pdf Quick Start Manual for Lighting Equipment Durite 0-441-15. Durite 0-441-15 2 pages. Led high intensity warning light

LED High Intensity Warning Light
Part 0-441-15
FLASH PATTERNS
1. Switch Patterns:
(Yellow wires touch Red wires)
To cha nge t o ne xt flash pattern:
With the LED Light Heads switched on, momentarily apply + VD C to YELLO W wires for less than 1 sec-
o nd a n d re lease
To reset:
With the LED Light Heads switched on, quickly apply three times + VDC to YELLO W wires and release.
LED Light Head will reset to the factory default pattern (Pattern # 0, Rando m)
2. Synchronization: (More than 2 sets of LED Light Heads)
First, connect Y ELLO W wires of all heads together, quickly apply three times + VDC to Y ELLO W wires
and release fo r Pattern # 0, Ra nd o m.
Secondly, mo me ntarily apply + V D C to Y E L LO W wires to for less than 1 second and release for Pattern
# 1, then the synchronization will be functioned.
3. Alternating or Simultaneous Flash: (More than 2 sets of LED Light Heads)
Under Synchronization, connect W HITE wire of LED Light Head 1 to Red wires of all other LED Light
Heads;
LED Light Head 1 will alternate with other LED Light Heads.
If the W HIT E wire not connected to Red wires, all LED Light Heads will flash together (Simultaneous
flash)
4. Flash Patterns: 20 selectable strob e patterns
SPECIFICATION
Type
Ultra high intensity LED
Red / Amber
Colour
Number of LEDs
6 x 3 watt
Voltage
12/24 volt dc
Current
0.70 a mp s at 12volts
Fla s h patterns
20
Base
Alu minum
Ope rat in g t e mp e ra t ure
-20C - +50C
Protection
IP68
Weight
40g
Dime nsions
l 113 x w 28.4 x h 9 m m
Co mpliance
UKCA,ECE R10 R65
WWW.DURITE.CO.UK
1. Switch Patterns:
To cha nge t o ne xt flash pattern:
With the LED Light Heads switched on, momentarily apply + VD C to YELLO W wires for less than 1 sec-
o nd a n d re lease
To reset:
With the LED Light Heads switched on, quickly apply three times + VDC to YELLO W wires and release.
LED Light Head will reset to the factory default pattern (Pattern # 0, Rando m)
2. Synchronization: (More than 2 sets of LED Light Heads)
First, connect Y ELLO W wires of all heads together, quickly apply three times + VDC to Y ELLO W wires
and release fo r Pattern # 0, Ra nd o m.
Secondly, mo me ntarily apply + V D C to Y E L LO W wires to for less than 1 second and release for Pattern
# 1, then the synchronization will be functioned.
3. Alternating or Simultaneous Flash: (More than 2 sets of LED Light Heads)
Under Synchronization, connect W HITE wire of LED Light Head 1 to Red wires of all other LED Light
Heads;
LED Light Head 1 will alternate with other LED Light Heads.
If the W HIT E wire not connected to Red wires, all LED Light Heads will flash together (Simultaneous
flash)
4. Flash Patterns: 20 selectable strob e patterns
Type
Colour
Number of LEDs
Voltage
Current
Fla s h patterns
Base
Ope rat in g t e mp e ra t ure
Protection
Weight
Dime nsions
Co mpliance
0-441-15-LEAFL
LED High Intensity Warning Light
Part 0-441-15
FLASH PATTERNS
(Yellow wires touch Red wires)
SPECIFICATION
Ultra high intensity LED
Red / Amber
6 x 3 watt
12/24 volt dc
0.70 a mp s at 12volts
20
Alu minum
-20C - +50C
IP68
40g
l 113 x w 28.4 x h 9 m m
UKCA, ECE R10 R65
WWW.DURITE.CO.UK
0-441-15-LEAFL