DURKOPP ADLER 0867 590114 Instructions Manual - Page 13

Browse online or download pdf Instructions Manual for Sewing Machine Accessories DURKOPP ADLER 0867 590114. DURKOPP ADLER 0867 590114 16 pages. Fitting remaining thread monitor for var. kits

DURKOPP ADLER 0867 590114 Instructions Manual
Anbauanleitung des Restfadenwächters
Instructions for fitting remaining thread monitor
3.3
Screwing on and connecting the valve
1
2
Ausgabe/Edition:
10.2006
für div. Bausätze (siehe Pkt 1.1)
for var. kits (see section 1.1)
Pre-assemble the valve 1, make sure to mount the sealing
washer properly.
Screw on the valve 1 to the valve rail, for this purpose remove
the valve unit.
Screw on the valve unit again.
Connect the hose from the light barrier to the valve. If you are
intending to use both light barriers, left and right, connect the
hose using the 'Y' junction 2.
Attach the hose and the cable to the oil return line hose and
to the shaft of the knee lever with the clamps.
Connect electrically the solenoid valve to the valve circuit
board
- in case of extreme soiling X22 (3), PIN 1/7/8 (+)
and PIN 4 (FL)
- in case of moderate soiling X22 (3), PIN 1/7/8 (+)
and PIN 2 (FA)
Printed in Federal Republic of Germany
3
(X22)
Teile-Nr./ Part-No.:
0791 867702
Blatt:
von
Sheet: 13