Data-Tronix DT-UPS-1200 Manual - Page 5
Browse online or download pdf Manual for UPS Data-Tronix DT-UPS-1200. Data-Tronix DT-UPS-1200 8 pages. Dt-ups series
■ Operating by the LED display mode 1 ((Reference the figure 8):
1.
ON/OFF BUTTON---- Turn ON this button to supply power to the UPS outlets. To switch off power to the
UPS outlets turn OFF the switch. This switch is situated on the front panel of the UPS.
2.
AC NORMAL INDICATOR (Green light continuous) ---The UPS is supplying conditioned utility power to
its outlets.
3.
CHARGING INDICATOR (yellow light continuous) ---The UPS is supplying conditioned utility power to its
outlets and the battery is charging.
4.
BACKUP INDICATOR (red light slow blinking) ---The indicator starts slow blinking when utility power is
outside acceptable limits. The battery is powering the UPS outlets.
5.
SLOW BEEPPING----A one second duration tone is sounded two seconds after utility power loss has
occurred. The UPS will continue to run with an audible alarm until a low battery condition is reached.
6.
LOW BATTERY INDICATOR (Red light fast blinking) ---The indicator starts fast blinking whenever the
battery is near the end of its runtime.
7. FAST BEEPING----The UPS is near the end of its battery runtime promptly save your data and exit all
applications and shutdown the operating system.
■Operating by the LED display mode 2 ((Reference the figure 9):
1.
ON/OFF BUTTON ----Turn ON this button to supply power to the UPS outlets. To switch off power to the UPS
outlets turn OFF the switch. This switch is situated on the front panel of the UPS.
2.
AC NORMAL INDICATOR (Green light continuous) ---The UPS is supplying conditioned utility power to its
outlets.
3.
BACKUP INDICATOR (yellow light slow blinking) ---The indicator starts slow blinking when utility power is
outside acceptable limits. The battery is powering the UPS outlets. The expected runtime for a typical personal
computer (PC) is about 10 to 20 minutes.
4.
SLOW BEEPPING----A one second duration tone is sounded two seconds after utility power loss has occurred.
The UPS will continue to run with an audible alarm until a low battery condition is reached.
5.
FAULT INDICATOR (Red light fast blinking) ---The indicator starts fast blinking whenever the battery is near the
end of its runtime.
6.
FAST BEEPING----The UPS is near the end of its battery runtime promptly save your data and exit all
applications and shutdown the operating system.
Manual Shutdown
When the UPS is operating on battery the procedure below can be performed to conserve battery charge and not allow
the connected equipment to have power removed without being properly shut down..
1. Save important working files.
2. Exit all applications
3. Exit the operating system
4. Shut down the connected equipment.
5. Turn off the UPS ON/OFF Switch which is situated on the front panel of the UPS.