FIGURE 6 - Electrical Connections
TO LAMP
MOTOR
OUTPUT
LAMP
OUTPUT
TRANSFORMER
TERMINALS
If the connection to the "T" terminal is more than 2.5m long, then a separate single core wire MUST
be used. (To avoid "nuisance" triggering of the fan)
OPERATING
SWITCH
For fixed wiring circuits the protective fuse
for the appliance must not exceed 5A.
LAMP INPUT
(FROM TRANSFORMER)
TO MOTOR
MOTOR INPUT
(FROM TRANSFORMER)
FUSE*
ISOLATING
SWITCH
(FOR ALL POLES)
MAINS
INPUT
(FIXED WIRING)