1.4 TECHNICAL FEATURES:
Motor Voltage
Max Absorbed Power
Nominal Thrust
Power Supply
Nominal Input Current
Motor Speed
Maximum Gate Weight
Duty Cycle
Operating Temperature
Gate Weight
1.5 Installation
A. CHECKS BEFORE INSTALLATION
Before proceeding with the installation check the following:
1. The structure of the gate should be suitable for automation.
2. The gate should be supported by upper guides.
3. Mechanical end stoppers must be provided to prevent the gate from running off the track.
4. The foundation should be strong enough to support the operator.
5. There are no cables or pipes in the path of the operator and the gate.
6. Be sure that gate moves freely.
7. There are no obstacles in the moving gate area.
8. The operator is not in a position where it can be easily or accidently damaged by passing
vehicles.
9. The 2 x limit magnets should have different marking on them. One should have a
other should have a
magnets can be installed on either side (open or close). Please see the diagram below to locate
the marking on the magnets.
4
24Volts DC motor
80 Watts
240 Volts AC
2 Amps
15 m/min
60% over 12 min
-20°c - +50°c
Up to 600Kg on level
ground
.You cannot use the limit magnets if they have the same marking. The
AXIOM SLIDING GATE OPENER MANUAL
iS600
220N
600 kg
Up to 900Kg on level
iS900
24Volts DC motor
120 Watts
330N
240 Volts AC
3 Amps
15 m/min
900 kg
60% over 12 min
-20°c - +50°c
ground
and the