Elsema G-2025 Manual - Page 12
Browse online or download pdf Manual for Receiver Elsema G-2025. Elsema G-2025 14 pages. 4g receiver with relay output for opening sliding, swing gates, doors or switching devices

When inputs 1 & 2 are triggered, it will stay in alarmed status for 1 minute and the siren output switches ON.
The Digital inputs 1 & 2 will only trigger an alarm in the following conditions:
1. The GSM receiver is in armed mode
2. 10 minutes after the last call from an authorized user. Factory default is 10 minutes but this time can be
changed. (minimum is 1 minute)
3. Digital Inputs 1 & 2 will re-arm after 30 seconds from a sensor input.
Changing the time after which Input 2 becomes active
PwdDtime#
o
Time: 000—999 in minutes. 000 means the GSM receiver will always be disarmed
E.g If the user wishes to change the time to 2 minutes after which input 2 becomes active, the following
SMS command is needed (minimum is 1 minute).
1234D002#
Power failure SMS
PwdACtime#
o
Time: 000—999 in minutes.
000 means the GSM receiver will send SMS message to the 1
999 means no SMS message will be sent when AC power fails.
Self-diagnostic SMS report to the 1
PwdT#time#
o
Time: 000—999 in hours.
000 means the GSM receiver will not send any message.
Self-diagnostic SMS will include the following:
Arm / Disarm Status;
Digital Input 1 & 2 status;
Relay status;
Mobile signal strength (31 is strong signal, lower than 14 is weak signal)
AC power supply status
Checking the Self-diagnostic SMS report time and status
PwdT#
o
Check current status
PwdEE
o
www.elsema.com
st
user when the AC power fails.
st
user
Page 12
ELSEMA
4G Receiver with relay output, G-2025