Although the unit is protected against electromagnetic disturbance, excessive disturbance can affect the
operation, measurement precision and data communication quality.
Use cables of appropriate temperature range.
Use adequate cable section, at least 0.75mm
For current transformer inputs, use at least 1.5mm
The current transformer cable length should not exceed 1.5 meters. If longer cable is used,
increase the cable section proportionally.
Follow national rules for electrical installation.
Current transformers must have 5A output.
Supply voltage: 85-305 V AC (L1-NEUTRAL)
Supply frequency: 45-65Hz
Measurement inputs:
Voltage:
Current:
Frequency:
Accuracy:
Voltage:
Current:
Frequency:
Power (kW,kVAr): %1.0 + 2 digit
Cos:
Measurement range:
CT range:
VT range:
kW range:
Power consumption:
ELECTRICAL CONNECTIONS
Do not install the unit close to high electromagnetic noise
emitting devices like contactors, high current busbars,
switchmode power supplies and the like.
Current Transformers must be used for current measurement.
No direct connection allowed.
TECHNICAL SPECIFICATIONS
10 - 305 V AC (P-N)
20 - 530 V AC (P-P)
0.2 - 6.00 A AC
30 - 100 Hz
% 0.5 + 1 digit
% 0.5 + 1 digit
% 0.5 + 1 digit
%2.0 + 2 digit
5/5A to 5000/5A
0.1/1 to 200.0/1
0.1 kW to 6.5 MW
< 4 VA
2
(AWG18).
2
section (AWG15) cable.
Loading:
Voltage inputs: < 0.1VA per phase
Current inputs: < 1VA per phase
Relay output:
Digital input:
Active level:
Min pulse:
Isolation:
Operating temp. range: -20°C to +70 °C
Max. Relative humidity: 95% non condensing
Enclosure: Flame retardent, ROHS
compliant, high temperature ABS/PC
(UL94-V0)
Installation: DIN rail mounted
Dimensions: 70x115x66mm (WxHxD)
Weight: 200 g (approximative)
EU Directives:
2006/95/EC (LVD)
2004/108/EC (EMC)
5A @ 250V AC
5 - 30V DC or AC
250ms.
1000V AC, 1 minute
-4 °F to 158°F
Reference
standards:
EN 61010 (safety)
EN 61326 (EMC)