Troubleshooting

Please follow the instruction in the manual in order to keep the amplifier work in its best state. If wrongly
operated and you thought that would be troubles please check according to following tips to look for the exact
reasons.
Problem
Backlight of the Meter is Off
Backlight of the Meter is On
Sound Distortion
Noise output
Sound field Positioning
is not so good.
NOTE:
Power cord is not well-connected.
Main fuse is out.
Troubles of inner parts or components.
Volume is at ZERO.
NO signal input.
High input signal level.
Ground of input signal cable is open
or bad contact of the input signal
cable.
Components or circuits are in trouble.
Signal input cables or speaker
cables are wrongly connected.
is the registered trademark of Zhuhai Spark Electronic Equipment Co., Ltd.
Cause
Remedy
Check power cable connection
or power outlet connection
Replace with the same type
and value fuse.
Please contact with local
agents or our company.
Turn up the Volume.
Check the function of the
sound source.
Check the input selection and
switch to the proper input.
Turn down the volume to
suitable
position
.
Replace the input signal
cable with a new one.
Please contact with local
agents or our company.
Reconnect it as suggested in
the manual.