Elsner 10150 Technical Description, Installation Instructions - Page 19

Browse online or download pdf Technical Description, Installation Instructions for Controller Elsner 10150. Elsner 10150 20 pages. Radio control system
Also for Elsner 10150: Operation (13 pages)

Elsner 10150 Technical Description, Installation Instructions
DANGER!
Risk to life from live voltage!
In operation the lid must be screwed on.
For removal, the weather station can be pulled out of the holder upwards against the
resistance of the notch.
4.6. Instructions for assembling the weather sta-
tion
Do not open the weather station if water (rain) can get into it: Even a few drops can
damage the electronics.
During installation care must be taken that the temperature sensor (small circuit board
on the underside of the housing) is not damaged. The cable connection between the
board and the rain sensor should also not be torn off or bent when being connected.
Remove all transport protection stickers present after installation.
The wind value measured is outputted ca. 30 seconds after the power supply has been
connected.
Solexa II Control • from software version 1.9
Version: 28.09.2016 • Technical changes and errors excepted.
19
Ill. 20
Screw the lid on to the underpart, to prevent
unauthorised or accidental opening.
Ill. 21
Push the casing from above into the installed
holder. In doing this, the studs in the holder
must click into the tracks on the casing.
Installation/assembly