Datalogic CBX500 Installation Manual - Page 6
Browse online or download pdf Installation Manual for Barcode Reader Datalogic CBX500. Datalogic CBX500 16 pages. Scanning connection box
Also for Datalogic CBX500: Installation Manual (17 pages), Installation Manual (17 pages)
CBX500 INSTALLATION MANUAL
MECHANICAL INSTALLATION
CBX500 can be mounted to various wooden or plastic surfaces using the two self-threading screws (3.9 x 45 mm)
and washers provided in the package.
Mounting to other surfaces such as concrete walls or metallic panels requires user-supplied parts (screws, screw
anchors, nuts, etc). A mounting template is included in the package to facilitate hole drilling alignment.
CBX500 can also be mounted to a DIN rail or a Bosch Frame using the following mounting accessories: BA100
(93ACC1821), BA200 (93ACC1822).
The diagram below gives the overall dimensions of the CBX500 and shows the two mounting through-holes.
180
[7.1]
ELECTRICAL CONNECTIONS AND SETUP
The following figure shows the typical layout.
Reading Device
Configuration PC
The dotted line in the figure refers to an optional (temporary) hardware configuration in which a portable PC can
be quickly connected to the CBX500 (and consequently to the reading device auxiliary interface) through the
internal 9-pin connector. This allows monitoring of the data transmitted by the reading device or configuration
6
Mounting
Holes
mm
in
Figure 1 - Overall Dimensions
PWR
PS, I/O, Main Interface
Scanner
Auxiliary
Interface
CBX500
Figure 2 – System Layout
80.9
4
[3.18]
[0.16]
82.9
[3.26]
Scanner