CBX500 INSTALLATION MANUAL
PINOUT
Group
Name
Vdc
Input Power
GND
Earth
+V
I1A
External
Trigger Input
I1B
-V
+V
I2A
Generic Input
I2B
-V
+V
-V
O1+
Outputs
O1-
O2+
O2-
O3A
O3B
+V
I3A
Other I/O
I4A
-V
I34B
I34B
TX
Auxiliary
RX
Interface
SGND
REF
ID-NET™
ID+
ID-
Network
Shield
Main
Interface
The input power signals Vdc, GND and Earth as well as the network signals REF, ID+, ID-
and Shield; and RTX+, RTX- and SGND are repeated to facilitate system cabling. In this way
the power and network busses can enter and exit the CBX500 from different spring clamps
but be physically connected together.
* Do not leave floating, see Reading Device Reference Manual for connection details.
10
Pinouts
Function
Power Supply Input Voltage +
Power Supply Input Voltage -
Protection Earth Ground
Power Source – External Trigger
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Power Reference – External Trigger
Power Source – Inputs
Input 2A (polarity insensitive)
Input 2B (polarity insensitive)
Power Reference – Inputs
Power Source – Outputs
Power Reference – Outputs
Output 1+
Output 1-
Output 2+
Output 2-
Output 3A (polarity insensitive)
Output 3B (polarity insensitive)
Power Source – Other I/O
Input 3A (polarity insensitive)
Input 4A (polarity insensitive)
Power Reference – Other I/O
Input 3B and 4B (common) (polarity insensitive)
Input 3B and 4B (common) (polarity insensitive)
Auxiliary Interface TX
Auxiliary Interface RX
Auxiliary Interface Reference
Network Reference
ID-NET™ network +
ID-NET™ network -
Network Cable Shield
RS232
TX
RTS
RX
CTS
SGND
RS485FD
TX+
TX-
*RX+
*RX-
SGND
RS485HD
RTX+
RTX-
SGND