ELECTRICAL CONNECTIONS AND SETUP
The following figure shows the typical layout.
Reading Device
Configuration PC
The dotted line in the figure refers to an optional (temporary) hardware configuration in which
a portable PC can be quickly connected to the CBX500 (and consequently to the reading
device auxiliary interface) through the internal 9-pin connector. This allows monitoring of the
data transmitted by the reading device or configuration through the utility program (see the
reading device Installation Manual for more details). The reading device auxiliary interface
signals are also available on the internal spring clamp connectors.
After making system cabling and switch settings, connect the reading device to the 25-pin
connector on the CBX500 housing.
Switch ON the CBX500 power switch (see Figure 3). The Power LED turns on (blue) when
the power connection has the correct polarity. The Power LED turns on (red) in case of
wrong polarity.
After system functioning has been verified, close the CBX500 using the four cover screws.
PWR
PS, I/O, Main Interface
Scanner
Auxiliary
Interface
Figure 2 – System Layout