Datalogic DS2400N Quick Reference Manual - Page 3

Browse online or download pdf Quick Reference Manual for Barcode Reader Datalogic DS2400N. Datalogic DS2400N 20 pages. Datalogic laser scanner quick reference guide

STEP 1 – CONNECT THE SYSTEM
To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout
the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232
auxiliary interface can be used to transmit data independently from the main interface selection. When On-Line
Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object
enters its reading zone.
PG 6000
DS2400N
CBX100/500 Pinout for DS2400N
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the
DS2400N reader is connected by means of the CBX100/500:
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference – Inputs
Shield
Network Cable Shield
* Do not leave floating, see Reference Manual for connection details.
Do not connect GND, SGND and REF to different (external) ground references. GND, SGND
and REF are internally connected through filtering circuitry which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
MAIN
I/O, AUX
*
P.S.
Figure 1 – DS2400N in Stand Alone Layout
CBX100/500 Terminal Block Connectors
Power
Inputs
Shield
Main Interface
RS232
TX
RTS
RX
CTS
SGND
CBX100/500
* Presence Sensor
(for On-Line mode)
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
REF
Network Reference
ID+
ID-NET™ network +
ID-
ID-NET™ network -
RS485 Full-Duplex
TX+
TX-
*RX+
*RX-
SGND
DS2400N QUICK GUIDE
Host
Outputs
ID-NET™
RS485 Half-Duplex
RTX+
RTX-
SGND
3