Datalogic DS4800 Quick Reference Manual - Page 7

Browse online or download pdf Quick Reference Manual for Barcode Reader Datalogic DS4800. Datalogic DS4800 16 pages.
Also for Datalogic DS4800: Quick Reference Manual (13 pages), Quick Reference Manual (13 pages)

Datalogic DS4800 Quick Reference Manual
Connectivity:
DX8200 Controller is always Master on the Lonworks network. It interprets data from each Slave scanner and
performs the correct barcode assignment to the parcel using the PackTrack™ operating mode.
External devices such as a presence sensor and an encoder are all connected to the DX8200 Controller, which is
also connected to a Host PC.
A single DX8200 Controller provides a Lonworks communication line having up to 5
requires the termination connector BTK-8000. The maximum allowable length for the entire bus cabling is 65 m.
The following figures show 2 possible layouts for the DX8200 Controller.
Bus Interface SLAVE Scanners
1
BTK-8000
PWR-120/240/480
1
CAB-8305
** Presence Sensor connected to External Trigger Input
*
The maximum number of scanners on the Lonworks cluster is 6 (1 DX8200 controller + 5 slaves). Positive environmental
conditions (i.e reduced number of barcodes, conveyor speed, reading area dimensions...) to be evaluated case by case, may
further increase the number of slaves up to the theoretical limit of 13.
DX8200 Controller MASTER Scanner
(VAC model)
...
85-260 VAC
DATALOGIC CAB-810X CABLES
DX8200 Controller MASTER Scanner
(VDC model)
Bus Interface SLAVE Scanners
2
3
DATALOGIC CAB-810X CABLES
85-260 VAC
...
PRESENCE
SENSOR**
ENCODER
DX8200 CONTROLLER
QUICK GUIDE
*
scanners. The last scanner
85-260 VAC
HOST
PRESENCE
SENSOR**
ENCODER
HOST
7