2.3. Notes on mounting and commissioning

Device must not be exposed to water (rain). This could result in the electronic being
damaged. A relative air humidity of 95% must not be exceeded. Avoid bedewing.
3.

Operation

3.1. Central operation
The central input of the MSG1-UP allows e. g. an automatic control unit, a timer or
even a normal unlocked twin push button (Up/Down) to be connected. The central
command (continuous voltage) always has priority over a movement command from
the manual input.
If there are "Up" and "Down" movement commands at the central input at the same
time, the drive moves up (secure position).
The central control unit can be set to the operating modes "Lock" (default) or "Dead
man". By simultaneously pressing the Up and Down buttons at the manual input, you
can switch between the operation modes:
1. Press the buttons Manual-Up and Down simultaneously for 5 seconds,
in order to set the device to readiness for change.
OR
Switch the mains voltage briefly off and on again.
After the mains voltage is connected, the device is also in a state of readiness for
change.
2. The device is now ready for change and it indicates the currently active mode via
the mode-LED.
Motor Control Unit MSG1-UP • Stand: 03.03.2016 • Technische Änderungen und Irrtümer vorbehalten.
5
Central command
Button
Manual command
Operation
Button
Manual