Additional WGTH-UP indoor sensors (optional) for additional temperature
and humidity measurement at various places in the room. This allows
various climate areas to be realised (e. g. living and plant areas in the
conservatory)
•
Radio remote control Remo 8
•
RF relay (radio relay, On/Off)
•
RF MSG (radio motor control device, Up/Down)
The following additional options are available:
•
Connection of up to 10 external Up/Down wall buttons for manual operation
of drives and devices on the spot
•
Connection of up to 2 video cameras via an optional camera interface
•
Communication with the KNX bus system via an optional KNX interface
Automatic functions in overview
Devices connected via the "Dimmer" output (e.g. lighting) have no automatic
functions. They can however be operated manually via the display.
Sliding doors also have no automatic functions. They can be fitted with a close-
contact (to a multifunctional input) and be manually operated via the display.
Automatic functions for window/sliding roofs:
•
Opening above a selectable indoor temperature (can be switched off)
•
Opening above a selectable air humidity level in the room (can be switched
off)
•
Keep closed beneath a selectable outdoor temperature (can be switched off)
•
Close when the supply air temperature is higher than the room temperature
•
Close when there is precipitation or move to a gap (can be switched off)
•
Closing when a selectable wind speed is exceeded (can be switched off)
•
Daily forced closure (settable running times)
•
Night-time re-cooling (settable running times)
•
Keep closed in a period which can be set
•
Closing when cooling/air-conditioning unit is active
If a motion detector is connected, windows will be closed automatically when a
break-in alarm is triggered. If a smoke detector is connected, windows will be
opened automatically when a fire alarm is triggered.
Step windows will be opened step-by-step. An opening position can be set for
sliding windows.
9