Datalogic S62-PA-2/5 Instruction Manual - Page 4
Browse online or download pdf Instruction Manual for Accessories Datalogic S62-PA-2/5. Datalogic S62-PA-2/5 4 pages.
S62...M
Background suppression
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates that the N.O. output is closed and the N.C.
output is open.
STABILITY LED (green) (S62...M2/M3)
When permanently ON, the green LED indicates a normal operating condition
where the received signal has a safety margin superior to 30% respect to the
output switching value. The sensor is ready to function correctly (stability
condition).
POWER ON LED (green) (S62...M0/M1)
The green LED ON indicates the powering status and the laser emission
presence.
DISTANCE ADJUSTMENT TRIMMER (ADJ.)
A 6-turn trimmer allows the background suppression distance adjustment
through a mechanical variation of the optic triangulation angle.
The operating distance increases, rotating the screws in a clockwise direction.
Please refer to the "SETTING" paragraph for acquisition or setup procedure
indications.
POSITION INDICATOR
This indicator presents a scale numbered from 1 to 6 that allows a precise
adjustment of the suppression distance in the entire operating range.
Please refer to the "SETTING" paragraph for use indications.
TIMER ADJUSTMENT TRIMMER (S62...M05/M15/M25/M35)
This control allows to vary the output delay deactivation from 0 to 1 sec.
Please refer to "TIMER FUNCTIONS" paragraph for use indications.
DARK/LIGHT TRIMMER (S62...M01/M11-PN)
The LIGHT/DARK mode is selected using a mono-turn trimmer.
LIGHT MODE: clockwise rotation
DARK MODE: counter-clockwise rotation.
WARNING: the maximum mechanical rotation range of the trimmer is 240°.
Do not force over of the maximum and minimum positions.
INSTALLATION
The sensor can be positioned by means
of the three housing's holes using two
screws (M4x25 or longer, 1.5Nm max.
tightening torque) with washers.
Various orientable fixing brackets to
ease the sensor positioning are available
(please refer to the general catalogue).
The operating distance is measured
from the front surface of the sensor
optics.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block of 180°.
CONNECTIONS
S62-PA-2/5...PN
S62-PA-2...PP/NN
S62-PA-5...PP/NN (M12 connector)
S62...M0-PP/PN/NN
Power supply:
Ripple:
Consumption
(output current excluded):
Outputs:
S62...PP/NN: PNP or NPN N.A./N.C. 30 VDC / S62...PN: NPN/PNP; 30 VDC max (short-circuit protection)
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Emission type:
Spot dimension:
6x6 mm (at 200 mm)
Operating distance (typical values):
30...300 mm
Adjustment:
Multiturn distance adjustment trimmer / Timer adjustment trimmer (S62...M05/M15/M25/M35)
DARK/LIGHT selection:
mono-turn trimmer (S62...M01/M11-PN)
Difference (90% white / 4% black):
< 8 %
Hysteresis (90% white):
Indicators:
OUTPUT LED (YELLOW) / STABILITY LED (GREEN)
Operating temperature:
Storage temperature:
Dielectric strength:
Insulating resistance:
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
UL requirements:
they are intended to be connected to a Class 2 transformer or class 2 power supply
Weight:
Suppression distance setting
1. Object detection
Position object to detect in front of the sensor at the distance required.
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and
green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON. Object detection condition (A status of position indicator)
A
2. Background suppression
Remove object and ensure that the background is in front of the sensor:
yellow LED OFF and green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON: background detection condition (B status of position indicator).
B
The trimmer reaches maximum level with yellow LED OFF if the background
is outside the operating range.
TECHNICAL DATA
S62...M1-PP/PN/NN
S62...M2-PP/PN/NN
10 ... 30 VDC
2 Vpp max.
40 mA max.
100 mA (overload and overvoltage protection)
2 V
500 s
1 ms
1 kHz
500 Hz
RED (660 nm)
INFRARED (880 nm)
15x15 mm (at 400 mm)
60...600 mm
60...1200 mm
< 12 %
< 25 %
< 5 %
OUTPUT LED (YELLOW) / POWER ON LED (GREEN)
-10 ... 55 °C
-20 ... 70 °C
500 VAC 1 min., between electronics and housing
>20 M 500 VDC, between electronics and housing
According to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
11 ms (30 G) 6 shock for each axis (EN60068-2-27)
ABS
PMMA window; PC lens
IP67
2 m cable 4 mm / M12 4-pole connector
90 g. max. cable vers. / 40 g. max. connector vers.
SETTING
Rotate trimmer in an anticlockwise direction until yellow LED turns OFF
and green LED ON: condition where background is outside operating
range (C status of position indicator).
C
3. Setting and control
Rotate trimmer in an anticlockwise direction until the indicator reaches
an intermediate point between position A and C.
If position A and C are close to each other, leave trimmer on position C.
The sensor is now ready to function correctly and in stable conditions:
DETECTION DIAGRAM
S62...M3-PP/PN/NN
50
42
1,5 ms
330 Hz
200x200 mm (at 2000 mm)
200...2000 mm
(recommended target 400x400mm)
-
11
6
< 30 %
< 20 %
TIMER ADJUSTMENT
TRIMMER (mod.M05/M15/M25/M35)
DARK/LIGHT
TRIMMER
(S62-M01/M11-PN)
6.18
10.7
OUTPUT LED
STABILITY LED (S62...M2/M3) /
STABILITY LED
POWER ON LED (S62...M0/M1)
TIMER FUNCTION (S62...M05/M15/M25)
The timer function allows to adjust the output deactivation delay when the
object is outside the detection area. The delay extends the output activation
allowing the slower interface systems to detect shorter pulses.
The delay adjustment is carried-out manually using the Timer adjustment
trimmer. Clockwise rotation increase the delay from 0 to a max. 1 sec. value.
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2007 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
DIMENSIONS
18
4.7
RECEIVER
EMITTER
14
M12
Ø15
14
11
CABLE VERSION
18.4
DISTANCE ADJUSTMENT TRIMMER
POSITION INDICATOR
mm
where installed.
826002875 Rev. G