Datalogic S70 Quick Start Manual - Page 3
Browse online or download pdf Quick Start Manual for Accessories Datalogic S70. Datalogic S70 10 pages. Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Also for Datalogic S70: Manual (18 pages)
TOP PANEL INTERFACE
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode
switch, LO/DO switch, +/SET/- Navigation key, dual red/green digital displays, and output LED.
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode.
RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the
+/SET/- button. PRG mode allows the sensor to be programmed through the display driven programming
menu (see Program Mode below).
ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode
below).
CH1/CH2 Switch
The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of the
display.
•
CH1 selects the Analogue Output
•
CH2 selects the Discrete Output
.
+/SET/- Navigation key
The +/SET/- Navigation key is a 3-way button. The +/- positions are engaged by rocking the button left/ right.
The SET position is engaged by clicking down the button while the rocker is in the middle position.
All three button positions are used during PRG mode to navigate the display driven programming menu.
During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the
threshold(s). The Navigation key is disabled during RUN mode, except when using Window SET (see
Window SET).
Red/Green Digital Displays
During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the
threshold.
During PRG mode, both displays are used to navigate the display driven programming menu.
Dual Output LED
The output LED provides a visible indication when the output is activated.
•
1 represents the Channel 1 analogue output. When on, it indicates that the signal is within the
analogue range.
•
2 represents the Channel 2 discrete output. When on, it indicates that the output is conducting.
Teach / Set methods
For more information about how to perform TEACH/SET methods, see the www.datalogic.com.
Run Mode
Run mode allows the sensor to operate normally and prevents unintentional programming changes.
In CH1 RUN mode, the +/SET/- Navigation key is used to view the analogue endpoints and midpoint signal values.
The +/SET/- Navigation key is disabled during CH2 RUN mode, except when using Window SET (see
3
Window
SET).