Datalogic S70 Manual - Page 10

Browse online or download pdf Manual for Accessories Datalogic S70. Datalogic S70 18 pages. Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Also for Datalogic S70: Quick Start Manual (10 pages)

Datalogic S70 Manual

Light SET

Sets a threshold a programmable % offset below the presented condition
Changes output state on any condition darker than the threshold condition
Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust)
Recommended for applications where only one condition is known, for example a stable light background with varying darker
targets
See
Program Mode
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition.
When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO switch setting (see
LO/DO Switch in
Top Panel
Interface).
Light SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
- GREEN display shows the switching threshold value
- 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Light SET:
Note: TEACH Selection must be programmed to Lt SEt (see
1. Enter Adjust Mode
Method
SET Button 11
Remote Input 12
SET Button: 0.04 seconds ” "Click" ” 0.8 seconds
11
Remote Input: 0.04 seconds ” T ” 0.8 seconds
12
for programming the Offset Percent setting
Output OFF
Darkest
(no signal)
Figure 6. Light SET (Light Operate shown)
Set Mode switch to ADJ
No action is required; sensor is ready for
Light SET method
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold a programmable
% offset below the
presented condition
Output ON
Condition
Most Light
Presented
(saturated
signal)
Program
Mode)
Action
10
Result
Display: Red - Signal Level;
Green - Threshold