2easy DT-SCU User Manual - Page 7
Browse online or download pdf User Manual for Intercom System 2easy DT-SCU. 2easy DT-SCU 8 pages. Camera interface
2).Working mode configuration, the camera switching time setting, and
monitoring time setting.
In the program state, press and
hold "CAM1" button for 3 seconds
to switch the working mode. Then
it will return to standby
Working mode
indicator:CAM(1~4)
(flash once)
[SCU mode] [DCU mode]:
(flash twice)
[DCU mode] [SCU mode]:
Note:In program state, if there isn't any operation within 10s, or press any button, it will
return to standby.
In the standby, press and hold
"CAM4" button for 3 seconds, it will
enter the state of program.
indicator:IN-USE
(flash)
In the program state, press
and hold "CAM2" button for 3
seconds, it will enter the state of
camera switching time setting.
(1)the left light of indicator CAM (1 ~ 4)
starts flashing (flash once per second);
(2)Flash once to increase 3 seconds;
(3)Press any button to confirm the
setting and return to standby.
Note:
1. The maximum can be set to
99 seconds, to 99 seconds, then
automatically save and return to standby.
2. 6 seconds by default.
-6-
In the program state, press
and hold "CAM3" button for 3
seconds, it will enter the state of
monitoring time setting.
(1)the right light of indicator CAM (1 ~ 4)
starts flashing (flash once per second);
(2)Flash once to increase 15 seconds;
(3)Press any button to confirm the
setting and return to standby.
Note:
1. The maximum can be set to 900
seconds, to 900 seconds, then
automatically save and return to standby.
2. 600 seconds by default.