iBoot Ver 1.5
Setup Page
The setup page consists of several sections. Each time a setting
is changed click on the Apply button for that section to save the
changes in iBoot.
network manager for more details. This will be automatically set if using DHCP
HTTP Port: This setting is used to allow access to iBoot on a port other than the
Web standard Port 80. If the port is changed, you will need to identify the port
number when you enter iBoot's IP address into your browser: if the new port is
9100 then use http://192.168.1.254:9100 to access iBoot.
After changing the port, a reboot is
necessary. Consult your Network
Administrator for available port
assignments. Click on the Reboot button
at the top of the page to install the new
port.
Page 14
Device Name: Set a 20
Character name to be
displayed on the top of
each web page.
Cycle Time: 0 to 999
seconds power cycle time.
This is the length of time
the power will be off during
a reboot. You can also
cycle power on for this
time.
IP address: Enter either a
new IP address, or address
0.0.0.0 to enable Automatic
IP addressing via DHCP.
Once you click Apply for
this section, also click the
Reboot button that will
appear at the top of the
page. The new IP address
will not take effect until the
unit is rebooted.
Subnet Mask: Change if
required. Consult your
network manager for more
details. This will be
automatically set if using
DHCP
Gateway: Change if
required. Consult your