AUSSIE ECO-CLEAN Monsoon 200 Maintenance Manual - Page 12

Browse online or download pdf Maintenance Manual for Pressure Washer AUSSIE ECO-CLEAN Monsoon 200. AUSSIE ECO-CLEAN Monsoon 200 13 pages. Monsoon series high pressure blaster three phase models

Australian Pump Industries
OVERSPEEDING
Do not operate machine at over maximum pump rpm. Over speeding can cause serious
pump damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass. Switch machine off within five minutes of ceasing
operation as excessive by-pass can cause heat build up in pump and subsequent
damage. Excessive bypass running voids warranty.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate at its rated pressure.
ADJUST.
Tampering with the pressure regulator will void warranty and can be
DANGEROUS.
CHECK NOZZLE MONTHLY
If pressure drops off check nozzle for wear. Nozzles should be replaced on a regular
basis (every month for machines in regular use, every three months for machines used
intermittently). Using the machine with the incorrect nozzle size or worn nozzle will void
warranty and can be DANGEROUS to the operator.
PRESSURE CLEANER DAILY CHECK LIST
Check pump oil level
"
Check engine oil level
"
Check nozzle for wear
"
Check all high pressure components for leaks:
"
gun/lance
"
HP hose
"
all fittings
"
Check water filter and clean if necessary
"
Check unloader, safety valve and thermal dump for leaks
"
All professional machines need to be thoroughly serviced every three months. The service
involved should include the engine manufacturer's recommendations (see separate Engine
Manual) and the following;
Change pump oil
"
Change gearbox oil (if applicable)
"
Check filter for foreign debris
"
Check unloader, safety valve and thermal dump for leaks
"
Check all HP components for leaks: Gun/lance, HP hose and all fittings
"
Replace nozzles
"
Check gearbox to engine key for wear, if key is worn see your local Aussie Eco Clean
"
Service Department
NB Damage generated by worn keys is not covered by warranty!
WEAR PROTECTIVE GOGGLES
12
Aussie Monsoon & Hurricane ... Operation & Maintenance Manual
WARNING

THREE MONTHLY REGULAR SERVICE

AND CLOTHING!
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 9894 4144 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]
DO NOT