C-TOP-1561-33 AS-I Bus version is euipped with the following
function:
- Position self-adjusting
- IO (PNP)
- Deviation of positional accuracy ±0.5mm
- Warning of positional deviation (prevent valve from slight leak)
- Function of manual operation
- Blue LED light: indicating the valve is turned on
- Red LED light: indicating the valve is turned off
- Red LED light flickers: indicating it doesn't reach target position or valve position is deviated by pipeline
pressure etc.
- Bus communication:AS-I BUS
Signal selection
Tacit approval