June 2016
SWITCH MACHINE OFF WITHIN TWO MINUTES OF CEASING OPERATION AS
EXCESSIVE BY-PASS CAN CAUSE HEAT BUILD UP IN PUMP AND SUBSEQUENT DAMAGE.
F.
Stopping the machine
Engine Drive:
1.
Set the engine speed control lever to low speed position. Allow machine to run for 1 minute
without load to cool before stopping.
2.
Turn engine ON/OFF switch to OFF
3.
If your machine has a recoil start, pull recoil start until compression resistance is felt. Store the
machine in this position to help prevent valve warping or sticking.
4.
Close fuel valve.
FAILURE TO CLOSE THE FUEL VALVE ON THE ENGINE CAN CAUSE FUEL LEAKAGE
WHEN THE MACHINE IS BEING TRANSPORTED!
5.
Pull the starter handle slowly and return the handle to its original position when resistance is felt.
This operation is necessary to prevent outside moist air from entering the combustion chamber.
Electric Drive:
1.
Turn off switch
Both Options:
1.
Turn off water supply.
2.
Pull gun trigger to release all pressure in the system, then LOCK THE TRIGGER.
3.
Hoses may now be disconnected from the machine.
Failure to release pressure before disconnecting the hose quick coupler will result in the quick coupler
o-ring seal blowing out. This o-ring must be replaced before operating machine.
WARNING: CHECK HP NOZZLES & REPLACE REGULARLY
If pressure drops off, check nozzle for wear. Nozzles should be replaced on a regular basis (every
month for machines in regular use, every 3 months for machines used intermittently.
machine with the incorrect nozzle size or worn nozzle will void warranty and can be dangerous to the
operator.
UNLOADER SETTING ... DO NOT ADJUST
The high pressure unloader on the machine is factory set to operate the pump at it's rated pressure.
DO NOT ADJUST. Tampering with the unloader will void warranty and can be dangerous.
WARNING .... DO NOT RUN ON EXCESSIVE BY-PASS
EXCESSIVE BY PASS RUNNING VOIDS WARRANTY!!
Aussie BB Hire Series ... Operation & Maintenance Manual
Aussie Pumps
Using the
7