COOK EPD Installation, Operation And Maintenance Manual - Page 3

Browse online or download pdf Installation, Operation And Maintenance Manual for Fan COOK EPD. COOK EPD 17 pages. Propeller wall fan

COOK EPD Installation, Operation And Maintenance Manual
Single Speed, Single Phase Motor
Ground A
L 1
T-1
Line
T-4
L 2
Ground B
When ground is required, attach to ground A or B with
no. 6 thread forming screw. To reverse, interchange
T-1 and T-4.
2 Speed, 2 Winding, Single Phase Motor
Ground A
T-1
T-4
Ground B
When ground required, attach to ground A or B with
No. 6 thread forming screw. To reverse, interchange
T-1 and T-4 leads.
Single Speed, Single Phase, Dual Voltage
Ground A
L 1
Link A
T-5
Link B
Line
J-10
Low Voltage
L 2
Ground B
When ground required, attach to ground A or B with
No. 6 thread forming screw. To reverse, interchange
T-5 and J-10 leads.
Typical Damper Motor Schematic
Fan
Motor
Transformer**
Second
Damper
Damper
Motor*
Motor
For 3 phase, damper motor voltage should be
the same between L1 and L2. For single phase
application, disregard L3. *Damper motors may be
available in 115, 230 and 460 volt models. The damper
motor nameplate voltage should be verified prior to
connection. **A transformer may be provided in some
installations to correct the damper motor voltage to the
specified voltage.
High Speed
L 1
Line
L 2
Low Speed
Ground A
Link A & B
T-5
J-10
Ground B
L3
L2
L1
Transformer**
3 Phase, 9 Lead Motor Y-Connection
3 Phase, 9 Lead Motor
Y-Connection
Low Voltage
208/230 Volts
4 5 6
1
2
3
7
8
9
L 1 L 2 L 3
To reverse, interchange any 2 line leads.
3 Phase, 9 Lead Motor Delta-Connection
3 Phase, 9 Lead Motor
Delta-Connection
Low Voltage
208/230 Volts
8
9
7
5
6
4
2
3
1
L 1
L 2
L 3
To reverse, interchange any 2 line leads.
2 Speed, 1 Winding, 3 Phase Motor
High Speed
1
L 1
2
3
Line
Motor
4
L 2
5
6
To reverse, interchange any 2 line leads. Motors
require magnetic control.
2 Speed, 2 Winding, 3 Phase
To reverse: High Speed-interchange leads T11 and
T12.
Low Speed-interchange leads T1 and T2. Both
Speeds-interchange any 2 line leads.
3
High Voltage
460 Volts
4 5 6
7 8 9
1 2
3
L 1 L 2 L 3
High Voltage
460 Volts
7 8 9
4 5 6
3
1 2
L 1
L 3
L 2
Low Speed
1
Together
2
3
Motor
L 1
4
L 2
Line
5
L 3
6
L 1
L 2
Line
L 3
Open