5.
Auxiliary Input 1
Has the following functions.
A - Deadman's handle. If this pin is connected to Gnd then the Pro-160 will
follow the active profile ramp down to zero, it will ramp up again when the
signal is removed.
B - Alternate profile. If this pin is connected to Gnd the Pro-160 will start up in
the alternate profile defined in the profile that was operating without the signal
present. This allows easy switching between any two profiles.
C - Limit 1. If this pin is connected to Gnd then the Pro-160 will invoke the
behavior defined for this limit. This will be available in version 2.3.
D - Emergency stop. If this pin is connected to Gnd then the Pro-160 will stop
immediately. It will not start up again until the signal is removed, and the
ignition has been turned off / on.
6.
Auxiliary Input 2
Has the following functions.
PRO-160 V2.0 10/19
C - Speed
Looks for a 5V pulse for
speed sensing application.
These inputs will be live in
version 2.3.