3. After decide the cooker hood height, measure the position of the holes
for hanging hood and inside chimney bracket. Drill 4 φ8 holes, 2 for
inside chimney bracket and 2 for hanging the hood,and keep the hood
level. The fixed position of the inside chimney bracket is the highest
place of chimney. See pic 2.
4. Screw two 4 x 30mm screws on the wall with wall plugs to fix the
hood,then use two 4mm x 40mm screws to fix the inside chimney
bracket.See Pic 2.
5. Put the glass according to the lead direction and way on the cooker
hood, and then use the screws to fix the glass.Attach the expansion pipe
onto the one-way-valve as shown below,and fix the pipe on the valve by
cable tie, then lay the expansion pipe to the wall outlet. See pic 3.
6. Dress the inside chimney into the outside chimney. See Pic 4.
7. Make the hood hang on the wall in the fixed position, adjusting the
cooker hood position, fix the cooker hood with safety screws.See Pic 5.
8. Put the two chimneys together onto the cooker hood body, meanwhile
adjust the height of the inside chimney into the suitable height, and fix the
inside chimney to the inside chimney bracket by screw, here should be