2easy DT-RLC User Manual - Page 8

Browse online or download pdf User Manual for Controller 2easy DT-RLC. 2easy DT-RLC 11 pages. Relay actuator

2easy DT-RLC User Manual
DT-RLC connect lock
Note:
1.
Here's lock type is
E-magnetic lock.
6. Light Control Mode
In light control mode, the DT-RLC
output; Support exit control button.
6.1 How to set the light working time
In light control mode:
1). Power-on within 5 seconds, short-circuit S2 up to 3 seconds, the IN-USE indicator
flash.
2). Short-circuit S1 up to 3 seconds, and the IN-USE indicator always light.
3). Short-circuit again S2, meanwhile, the time of short-circuit 1 seconds equal to
light working time 30 seconds.(the IN-USE indicator flashes once per second; The
maximum setting time is 900 seconds.)
4). After S2 released, saved unlock time, and exit the setting.
6.2 DIP setting for light
DIP
POWER
SUPPLY
allows to control lights; With configurable light timed
Bit State
OFF,OFF,OFF
Set to the first DT-RLC.
EM-LOCK
12V
S2
GND
NO
COM
NC
DT-RLC
Descriptions
-7-
Exit Button
*
1 2 3
S1
GND
Jumper position in 2-3