austriamicrosystems AS5145A Operation Manual - Page 2
Browse online or download pdf Operation Manual for Motherboard austriamicrosystems AS5145A. austriamicrosystems AS5145A 12 pages. Demoboard
AS5X45/AS5145A/B Demoboard OPERATIONAL MANUAL
This configuration uses the same USB hardware connection as above, but additionally the AS5000 Programmer GUI
software is running. The LCD display will be turned off and the Angle/Status bits will be displayed on the PC screen.
Some extra features as zero position programming can be achieved. The parameters will not be permanently
programmed. All the parameters will be lost when the demoboard is shut down. For a permanent device programming,
the "AS5000 Programmer" hardware should be used.
3.1
Graphic LCD display
The LCD display shows the realtime absolute angle position of the magnet with a resolution of 0.09° = 4096 positions
per revolution (AS5045/AS5145A/B) and the absolute value of the angle.
Turning the knob clockwise will increase the angle value until 359.9° (value 4095), then 0°.
The magnet status indicator is related to the magnet position. If the magnet is too close or too far away from the
encoder, "Magnet out of range" will be displayed.
Magnet indicator:
- Distance OK
- Magnet out of range
Bargraph representation of
the angle (0° to 359.9°)
Figure 2: LCD display in standalone mode (9V battery or USB powered without GUI)
3.2
PWM LED
The PWM LED is connected to the PWM output of the AS5045/AS5145A/B. The PWM output is a pulse width that is
proportional to the angle of the magnet.
The pulse width varies from 1µs to 4096µs with a repetition rate of 244Hz. Viewing the PWM signal on the LED results
in brightness that is proportional to the angle of the magnet. When the angle of the magnet is at 0°, the LED is almost
dark, as it is 1µs on and 4095µs off. Turning the knob clockwise towards higher angles increases the brightness of the
PWM LED, since the ON-pulse becomes longer and the OFF-pulse becomes shorter.
Likewise, the PWM output can be used as an analog output proportional to the angle, when the PWM signal is filtered
by a RC (or active) lowpass filter.
The PWM signal (digital 0 ~ 3.3V) can be directly taken from the connector J4.
3.3
MagINc and MagDECn
MagINCn and MagDECn are the magnetic field change indicators (magnetic field strength increase or decrease through
variation of the distance between the magnet and the device).
These outputs can be used to detect the valid magnetic field range. If both indicators lit simultaneously
(MagINCn = 0 and MagDECn = 0), the magnet is out of range, the airgap between the encoder and the magnet is too
high or too low. In that case, "Magnet out of range" will be displayed on the LCD display.
Revision 1.3, 22-Jul-2009
www.austriamicrosystems.com
Absolute angle value
12 bit resolution: 0 to 4095
Magnet angle value
from 0° to 359.9°
Page 2 of 12