6. Setup
A
Door Station ID Address
Up to 4 x Door Stations can be connected to one system. To find programming buttons A and B, remove steel
facia of door station
1)Power-on and within 5 sec
2)Press and hold button "B" for 3
seconds to enter programming
mode
background indicator
(flash)
B
A
Monitors with User Code 0~15 will response calls from Button A
Monitors with User Code 16~31 will response calls from Button B
Buzzer
beep+,beep
Press and hold both buttons "A"
and "B" for 3 seconds at the
same time
background indicator
(off)
Followed by pressing the "B"
button, each time you press "B"
button to replace the ID;
Note:The ID will cycle between
ID0
ID1
background indicator
ID0:
(flash one)
ID1:
(flash twice)
ID2:
(flash 3 times)
ID3:
(flash 4 times)
-10-
Buzzer
beep+,
ID2
ID3.
Buzzer
beep one
beep twice
beep 3 times