Browse online or download pdf User Manual for Lighting Equipment dymax 42337. dymax 42337 16 pages. Emitter led spot-curing emitters
▪
If emitter aperture glass is permanently contaminated it must be replaced for
safe operation.
Mounting/Connections
▪
Each emitter has two sets of M3 x 0.5 mm holes (Figure 1) that align with Dymax
stands and holders.
▪
When connecting the emitter to the controller, ensure proper strain relief to
prevent pinching or kinking of the interconnect cable.
▪
The cooling air intake on top of unit must be free flowing, do not cover.
▪
Exhausting air on sides must be given at least 1 mm (0.04") of clear space to
obstructions for safe use.
Figure 2. Bluewave® MX-150 Emitter Dimensions
BlueWave® MX-150 Emitter User Guide