Gacell ABC 1600 User Manual - Page 11

Browse online or download pdf User Manual for Battery Charger Gacell ABC 1600. Gacell ABC 1600 16 pages.

CHARGING CURVES

Primepowers ABC charger is extremely flexible when it comes to charging curves. When ordering a charger be sure
to inform the specifications needed so we can deliver a charger programmed for your needs. If nothing is said, the
charger will always be programmed to default. The charging curve for all battery topologies are available.
Defaul program - vented / valve-regulated parallel consumption, J –program
Charging phase
I1-fas
U1-fas
U2-fas
Traktionary batteries (Gel/AGM), M-/B-program
Charging phase
I1-fas
U1-fas
I2-fas
U2-fas

CHANGING OF CHARGING CURVE

Chargers that are ordered with setting "0" works only after setting the correct battery capacity.
Switches for setting the charge curve is accessible on the front panel to the left of the LED.
ABC Charger is designed for charging any kind of battery, and is equipped with about 15 different charging curves.
Remove the sticker and screw the knob to the desired charging algorithm.
Please contact your dealer for the list of charging curves
Exampel of changing the charging curve on ABC 1600W
ABC 600/800/1600 USER MANUAL

Vented, open

Voltage level
>1,4V/cell
2,4V/cell
2,3V/cell
Vented, open
Voltage level
>1,4V/cell
2,4V/cell
Max 2,8V/cell
2,26V/cell
Time
Max 12h
Max 12h
Unlimited
Time
Max 12h
Max 12h
Min 1h max 4h
Unlimited
Idavägen 11 SE-352 46

Valve-regulated, Gel

Voltage level
>1,4V/cell
2,35V/cell
2,3V/cell
Valve-regulated, Gel
Voltage level
>1,4V/cell
2,35V/cell
Max 2,8V/cell
2,26V/cell
|
+46 470 72 74 95
|
Time
Max 12h
Max 12h
Obegränsad
Time
Max 12h
Max 12h
Min 1h max 4h
Obegränsad
10