AFF 805 Owner's Manual - Page 3
Browse online or download pdf Owner's Manual for Water Pump AFF 805. AFF 805 7 pages. 10 ton open body air/hydraulic foot pump
OPERATING INSTRUCTIONS
BEFORE USING PUMP:
•
Check all system fitting and connections to be sure they are tight and leak free.
•
Check oil level in the reservoir before operating pump.
TO OPERATE PUMP:
•
Remove the filler plug without hole and replace with the filler plug with hole.
•
Remove the shipping plug from the air inlet hole and insert a 1/4" NPT quick air coupler.
•
Connect hydraulic pressure hose and/or pneumatic pressure hose.
•
Connect air supply line to the air coupler.
•
To activate the pump for ram extension depress the treadle/lever at air inlet valve end.
•
To retract ram plunger depress treadle/lever end marked "RELEASE."
•
To stop the pump and maintain pressure release the pedal and the lever will return automatically to the
neutral position.
•
If pump needs to be primed:
1. Press the pedal on the "RELEASE" end while pushing the valve under the pedal area
2. Hold for approximately 15 seconds
3. Repeat if necessary
4. Pump should be primed and ready for operation
Page 3