HHO Plus HYDROGEN TECH ECC230 AC User Manual - Page 8
Browse online or download pdf User Manual for Ultrasonic Jewelry Cleaner HHO Plus HYDROGEN TECH ECC230 AC. HHO Plus HYDROGEN TECH ECC230 AC 13 pages. Engine carbon cleaner
The amperage and hydrogen production will depend on the electrolyte concentration (15 grs/liter of KOH).
Please keep the machine working between 30A and 40A:
a) If the amperage is higher than 40A please add more water to dilute the solution and reduce the
amperage;
b) If the amperage is lower than 30A please add a little bit more electrolyte in order to raise the
amperage. We advise you to add small amounts and let the machine work for some minutes before
pouring more electrolyte if the amperage is still lower than 30A.