Gage Bilt GB730 Installation Manual - Page 5

Browse online or download pdf Installation Manual for Tools Gage Bilt GB730. Gage Bilt GB730 14 pages. Installation tool
Also for Gage Bilt GB730: User Manual (13 pages)

Gage Bilt GB730 Installation Manual

HOW TO USE THE GB730

WARNING:
Operator
WARNING:
It is required that eye protection and hearing protection be worn during operation.
WARNING:
Do not pull rivet in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from
operator, other persons working in the vicinity, foreign matter and liquid.
CAUTION:
Do not use beyond the design intent.
The tool is shipped with a plastic plug in the air inlet connector. The connector has a 1/4-18 female pipe thread to accept end-user air
hose fitting.
1. Remove plastic shipping plug from Swivel (A-249) and screw in your air fitting.
2. Attach Deflector (752122) to rear of head cylinder (730398).
WARNING:
Rotate deflector away from operator and other persons working in the vicinity.
3. Connect air hose to tool (3/8 minimum diameter air line is mandatory, 90 p.s.i. (6.2 bar) is recommended) and cycle tool ten times
by depressing and releasing the actuator lever assy (704343). (Clean dry air is recommended.)
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
4. Disconnect air hose from tool.
5. Select proper Nose Assembly and attach securely to the tool.
6. Connect air supply.
7. Insert rivet into Nose Assembly and the application then depress the actuator lever assy (704343). Upon releasing the actuator
lever assy (704343), the stem will eject to the rear of the tool.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
S/N: 2317 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
MUST
read and understand all warnings and cautions.
Image may not reflect
actual tool
5
Rev. 2/15