General Houskeeping
Daily
Remove lid and empty strainer basket
into bin. Replace basket and secure lid.
Open lid and remove, clean and replace
detachable wiper blades.
Weekly
14
Empty collection container into barrel.
This can then be taken away by a local
rendering company for recycling.
Use a brush to clear grease deposits
from the internal channel and external
pipe bend above the grease container.
Fill sinks with clean water and empty
to flush through unit. This keeps
freshwater in tank. Always ensure
water level is reaching wheels.
Tri-Monthly Maintenance
External Service Partner
ATTENTION!
In addition to the daily and weekly housekeeping, all Grease Guardian units must
receive one service inspection every 3 months to be completed by an approved
FM Environmental service provider only. Failure to implement this service could
result in impairment of unit performance or system failure.
The service will consist minimally of the following steps:
Unit pump out:
To remove both settled and suspended
solids. A thorough inspection and
cleaning of the heating element will
also be carried out each time
Inspection of all wear and tear parts
Including Wiper rubber, flow restrictor
rubber and lid seal gasket.
Replacement of parts if necessary
Electrical checks
Including controller, heater and motor
checks. Optimisation of components
will be made if necessary.